UL Metal Clad Cables
Southwire Metal Clad cables are suitable for use in branch, feeder and service power distribution in commercial, industrial, institutional, and multi- residential buildings. The cables can be fished or embedded in plaster and concealed for exposed applications. Installation can be in cable trays and approved raceways or under raised floors for information technology equipment conductors and cables.
Southwire Liquidtight Flexible Metal Conduit

UL Listed. CSA Listed. Oil-Resistant. Sunlight-Resistant. Temperature Rated -55C to 80C
Southwire Armorlite® Cables – Lightweight Aluminium Armor
Southwire Armorlite® cables are constructed using lightweight aluminium interlocked armor. The cables meet or exceed the requirements of UL 83, UL 1569, UL 1685 and Federal Specification A-A59544 (formerly J-C-30B). The cables also meet FT4/IEEE 1202 Vertical Cable Tray Flame Test and NFPA 70 (National Electrical Code), Article 330. They are listed for use in UL 1, 2 and 3 Hour Through Penetration Firestop Systems and are REACH/RoHS-2 (Chemical Limit) Compliant.

14/2 AWG. 600V. THHN/THWN Insulated Singles

14/2 AWG. 600V. THHN/THWN Insulated Singles

14/8 AWG. 600V. THHN/THWN. Dedicated neutral per phase

14/10 AWG. THHN/THWN Insulated Singles. Multiple Circuits

14/8 AWG THHN/THWN. 600V. Two Grounding Conductors

14/8 AWG THHN/THWN. 600V. Oversized Neutral Conductor

10/3 AWG THHN/THWN. 600V. Blue Armolite aluminium armor

14/2 AWG THHN/THWN. 600V. 16 AWG aluminium bond

1 AWG through 750 kcmil Copper THHN/THWN-2 Insulated Feeder

1 AWG through 750 kcmil Copper THHN/THWN-2 Insulated Feeder
AlumaflexTM Cables – Aluminium Armor
Southwire AlumaflexTM Type MC cables are rated at 90°C wet or dry. The aluminium conductors are cabled together and a binder tape is wrapped around the assembly. Aluminum interlocking armor is applied over the assembly. For Jacketed versions, a black flame retardant sunlight resistant PVC jacket is applied over the armor.

1/0 AWG-900 kcmil THHN/THWN. 600V. Aluminium Ground

1/0 AWG-900 kcmil THHN/THWN. 600V. Aluminium Ground

1/0 AWG-900 kcmil THHN/THWN. 600V. Aluminium Ground

1/0 AWG-900 kcmil THHN/THWN. 600V. Aluminium Ground

1/0 AWG-900 kcmil XHHW. 600V. Aluminium Ground

1/0 AWG-900 kcmil XHHW. 600V. Aluminium Ground
Duraclad Cables – Galvanised Steel Armor
Southwire Duraclad cables are constructed with solid soft-drawn copper circuit conductors (rated 90°C dry), redundant grounding provided by an armor assembly comprised of galvanised steel interlocked armor. The insulated circuit and grounding conductors are cabled together and wrapped with a binder tape.

14/6 AWG Copper THHN/THWN Insulated Singles. 600V

14/6 AWG Copper THHN/THWN Insulated Singles. 600V

14/8 AWG Copper THHN Insulated Conductors. 600V

14/2 AWG Copper Type ACTHH (THHN Singles). Bond Wire. 600V

14/10 AWG Copper 16 AWG Aluminum Bond Wire. 600V
Power & Control Cables – Aluminium Armor
Southwire offer a range of metal clad cables for power, control and fire safety applications. The phase conductors, ground, and control conductor assembly are cabled together and a binder tape bearing the print legend is wrapped around the assembly. Aluminum interlocking armor is applied over the taped assembly.

12/10AWG Copper THHN/THWN. TFN Insulated Singles. 600V

12/10AWG Copper THHN/THWN. TFN Insulated Singles. 600V

12/10AWG Copper THHN/THWN. Aluminium grounding. 600V

Fire Alarm Cable 14 & 12 AWG Type THHN/THWN. 600V
General Purpose Cables – Aluminium & Steel Armor
Southwire general purpose cables are constructed with copper conductors (rated 90°C dry). The insulated conductors are cabled together and wrapped with a binder tape bearing the print legend. Aluminum or steel interlocking armor is snugly applied over the assembly.

14/8 AWG Copper THHN. Aluminium Grounding. 600V

1 AWG to 750 kcmil Copper THHN/THWN-2. 600V

14/2 AWG Copper THHN/THWN-2 Conductors. XLPE Insulation

14/10 AWG Copper THHN/THWN-2 Insulated Singles. 600V

1⁄2 inch steel conduit. 10/14 AWG THHN/THWN Power. Control 16/2
Healthcare – Aluminium Armor
The conductors are cabled together and a binder tape bearing the print legend is wrapped around the cabled assembly. Aluminum interlocking armor is applied over the cabled assembly. With jacketed versions, the sunlight resistant, direct burial rated PVC jackets are applied over the armored cable assembly.

Jacketed 16 AWG THHN/THWN. Aluminium Grounding. 600V

14/8 AWG THHN. Full-Sized Aluminum Grounding. 600V

Type MC 14/8 AWG THHN. Full-Sized Al Grounding. 600V

12/10 AWG THHN/THWN & TFN. Aluminium Grounding. 600V