Canadian Cables
The Canadian Standards Agency (CSA) sets out the requirements for the Canadian Electrical Code (Part 2) with a maximum voltage rating of 600V to the standard CSA 22.2.
Part 210-11 of CSA 22.2 is designated for Appliance Wiring Material Products such as heavy-duty cables with an increased voltage rating and a higher temperature rating than ordinary panel wires. The standard applies to both single conductor and multi-core cables, either round, flat or coiled.
CSA Building Wire

No. 14, 12 & 10 AWG, Copper Conductors, 600V

No. 14 to 2 AWG, Copper Conductors, 600V

No. 6 & 2 AWG, Aluminum Conductors, 600V

No. 14 to 6 AWG, Copper Conductors, 600V

Soft bare copper conductors, thermoplastic insulation

Aluminium conductors, 600V, CSA approved for hazardous locations

Copper conductors, 12 & 10 AWG for Power, 16 AWG for Signal

Fire Alarm Signaling / Low Voltage Thermostat, Unshielded

Solid bare copper, PVC insulation; twisted without fillers, 30V

Aluminium conductors, 300V, non-metallic sheathed cable

Copper conductors, 300V, PVC/Nylon insulation

Copper Conductors, 300V, PVC / Nylon Insulation, PVC Jacket

Solid or stranded 3 or 4 bare copper conductors

Single copper conductors, XLPE insulation, sunlight resistant

Single copper conductors, XLPE insulation, sunlight resistant

Ground Cable, Single conductors, XLPE insulation

Ground Cable, Single conductors, XLPE insulation

Single aluminium conductor, 600V, 6 AWG to 1,000KCMIL

600V, 14 AWG to 1,000 KCMIL, Sunlight Resistant

Aluminium Conductors, XLPE Insulation, 1000V, Sunlight Resistant

1,000V, single copper conductors, Sunlight Resistant

600V, aluminium conductor, PVC Insulation, All Sizes Rated TWN75

THHN THWN-2 MTW / c(UL) T90 Nylon TWN75, Copper, 600V
CSA Lead Wire
CSA CL 1251 XLPE Insulation. Solid, Stranded or Tinned Copper
Bare stranded copper, laid parallel with PVC insulation
Bare Copper Conductors. Available in dark or intermediate colors only
Bare copper conductors,
thermoplastic insulation, 600V
Bare or tinned solid or stranded copper. 90°C, 600 Volts
Moisture Resistant. 600V/1000V. Flexible Stranded Copper
Solid or stranded tinned copper, PVC insulation. 90°C, 600V
Solid or stranded tinned copper conductors, PVC insulation, 300V
CSA Mining Cable
Solid or stranded copper, PVC insulation 3 or 4 twisted conductors
Stranded copper, Neoprene rubber insulation, red only
CSA TECK 90
Power Cable, CU 1000V, XLPE Insulation, FT4, Hazardous
1000V FT4 – Flame Retardancy Rating, Direct Burial
Copper Power Cable, TRXLPE Insulated, FT4, Hazardous
Copper Power Cable, EPR Insulated, FT4, Hazardous Locations
Copper Power Cable, TRXLPE Insulated, FT4, Hazardous Locations
Aluminium Power Cable, EPR Insulated, FT4, Hazardous Locations
Aluminium Power Cable, TRXLPE Insulated, FT4, Hazardous Locations
600V Multi Conductor, 14-10 AWG Copper, FT4, XLPE Insulation
14-10 AWG Copper, 1000V Multi Conductor, FT4, XLPE Insulation
8AWG -1000 Kcmil Copper, Multi Conductor, FT4, XLPE Insulation
Two Conductor 1000V Multi Conductor, FT4, XLPE Insulation
Three Conductor 1000V Multi Conductor, FT4, XLPE Insulation
Four Conductor 1000V Multi Conductor, FT4, XLPE Insulation
ARMOR-X PVC Cable, 3 Grounds, VFD Cable Type MC-HL, Copper
ARMOR-X PVC Power Cable, Ground VFD, 3 Conductor Copper
Copper Multiconductor, XLPE Insulation, No. 8 & UP
TTR-XLPE insulated (treeing resistant) armoured cable, FT4
EPR Insulation, FT4, -40C, HL, AG14 and 90°C rated, Harsh Environments
EPR Insulation, FT4, -40C, HL, AG14 and 90°C rated, Harsh Environments
XLPE Insulation, Copper Multiconductor, No. 14-10 AWG
TR-XLPE Treeing Resistant Insulation, FT4, -40C, HL, AG14
CSA HVTECK
Single Core 5kV
AIA PVC 5kV 100% CSA, Single Conductor, 90 Mils, No Lead EPR
AIA PVC 5kV 133% CSA, Single Conductor, 115 Mils, No Lead EPR
5kV 133% CSA, Single Conductor, 115 Mils Tree Retardant Polyethylene
5kV 133% CSA, Single Conductor, 115 Mils Tree Retardant Polyethylene
5kV 133% CSA, Single Conductor, 115 Mils, No Lead EPR
Single Core 8kV
8kV 133% CSA, Single Conductor, 140 Mils No Lead EPR
8kV 133% CSA, Single Conductor, 140 Mils No Lead EPR
Single Core 15kV
15kV 133% CSA, Single Conductor, 220 Mils No Lead EPR
15kV 133% CSA, Single Conductor, 220 Mils No Lead EPR
Single Conductor, 220 Mils Tree Retardant Cross Linked Polyethylene
Single Core 35kV
Single Conductor, 420 Mils No Lead Ethylene Propylene Rubber
35kV 133% CSA, Single Conductor, 420 Mils Tree Retardant Polyethylene
35kV 133% CSA, Single Conductor, 420 Mils Tree Retardant Polyethylene
Three Core 5kV
5kV 133% CSA, 3 Conductor, 115 Mils No Lead EPR
5kV 133% or 8kV 100% CSA, 3 Conductor, 115 Mils Tree Retardant Polyethylene
5kV 133% CSA, 3 Conductor, 115 Mils No Lead EPR
Three Core 8kV
Three Core 15kV
15kV 133% CSA, 3 Conductor, 220 Mils No Lead EPR
15kV 133% CSA, 3 Conductor, 220 Mils Tree Retardant Polyethylene
15kV 133% CSA, 3 Conductor, 220 Mils Tree Retardant Polyethylene
Three Core 35kV
35kV 133% CSA, 3 Conductor, 420 Mils No Lead EPR
35kV 133% CSA, 3 Conductor, 420 Mils Tree Retardant Polyethylene
35kV 133% CSA, 3 Conductor, 420 Mils No Lead EPR