Single Core MV Cable (MV-105)
Medium Voltage cables from 2kV to 35kV in copper or aluminium (incl. PV Wire)
Medium Voltage industrial cables are available in voltages from 2 kV to 35 kV in copper or aluminum single core conductors. EPR insulation is a very popular material but there are also XLPE options, followed by a copper tape shield and then jackets ranging from PVC, LSZH to CPE.
MV cables are suited for use in wet and dry areas, conduits, ducts, troughs, trays, direct burial, aerially supported by a messenger and where superior electrical properties are desired.
Southwire 2kV Power Cable 8awg – 2000 kcmil

Power Cable 2000 Volt Single Conductor Copper, Cross Linked Polyethylene (XLPE) insulation RHH/RHW-2

Power Cable 2000 Volt Single Conductor Copper, Ethylene Propylene Rubber (EPR) insulation RHH/RHW-2 Chlorinated Polyethylene (CPE) Jacket

CT RATED Type MV-90 Single Conductor Copper, Ethylene Propylene Rubber (EPR) SIMpull® Polyvinyl Chloride (PVC) Jacket CT Rated 1/0 and Larger

EPDM Insulation, CPE Jacket. RHH/RHW-2/RW90 MSHA Approved, Heavy Duty Flexible Tinned Copper Power Cable (HDFPC) DLO, Rated

RHH/RHW-2 Power Cable 2000 Volt Heavy Duty Single Conductor Copper, Cross Linked Polyethylene (XLPE) insulation RHH/RHW-2

RHW-2 Type SSR Power CableSingle AL Conductor. Photovoltaic (Type PV). XLPE Insulation. Sizes 6AWG through 1000 kcmil

RHH/RHW-2 Single Conductor Photovoltaic (Type PV) Power Cable 2000 Volt Aluminum Conductor XLPE Insulation. Sizes 6AWG through 1000 kcmil

Single Conductor Photovoltaic (Type PV) Power Cable 2000 Volt Copper Conductor XLPE Insulation. Heat, Moisture, Sunlight Resistant Rated RoHS 90°C
Southwire 5kV MV Power Cable 2awg – 1000 kcmil MV-105

Or 8KV 100% TS SIMpull® PVC MV-105, 5kV/8kV 115 Mils No Lead Ethylene Propylene Rubber (NL-EPR) 133%/100% Insulation Level, Tape Shield, Dual Rated UL/CSA

133% TS CPE MV-105 Type MV-105 115 Mils No Lead Ethylene Propylene Rubber (NL-EPR) 133% Insulation Level, Tape Shield, Chlorinated Polyethylene (CPE) Jacket, Dual Rated UL/CSA

PVC MV-105 Type MV-105 Single Conductor Aluminum, 115 Mils No Lead Ethylene Propylene Rubber (NL-EPR) 133% Insulation Level, Tape Shield, SIMpull® Polyvinyl Chloride (PVC) Jacket, Dual Rated UL/CSA

Airport Lighting Cable 5000V Non-Shielded Copper Conductor With Cross-Linked Polyethylene Insulation XLPE. Meets (FAA) specification L-824 C Underground Electrical Cable
Southwire 15kV MV Power Cable 2awg – 2000 kcmil MV-105

133% SIMpull® Insulation, PVC MV-105. Type MV-105, Single Copper, 220 Mils No Lead Ethylene Propylene Rubber (NL-EPR) Tape Shield, dual Rated UL/CSA

133% TS SIMpull® Insulation PVC MV-105. Type MV-105 Single Conductor Aluminum, 220 Mils No Lead Ethylene Propylene Rubber (NL-EPR) Tape Shield, SIMpull® PVC Jacket, UL/CSA

NLEPR Insulation 133% IL Black CPE-TP Jacket. MV 105 – Tray Rated – Sunlight Resistant – For Direct Burial, Single Copper, 220 Mils No Lead Ethylene Propylene Rubber (NL-EPR) UL/CSA

NLEPR Insulation 133% IL Black LSZH-TP Jacket. MV 105. Tray Rated. Sunlight Resistant. Direct Burial.. Copper, 220 Mils No Lead Ethylene Propylene Rubber 133% Insul. UL

TRXLPE Insulation 133% IL Black PVC Jacket. MV 105. Tray Rated. Sunlight Resistant. Direct Burial. Type MV-105 Copper, 220 Mils Tree Retardant Cross Linked Polyethylene (TRXLPE)
Southwire 25kV MV Power Cable 2awg – 2000 kcmil MV-105

NLEPR Insulation 133% IL Black SIM-PVC Jacket. MV 105. Tray Rated. Sunlight Resistant. Direct Burial. Copper, 320 Mils No Lead. pal Rating UL/CSA

NLEPR Insulation 100% IL Black SIM-PVC Jacket. MV 105. Tray Rated. Sunlight Resistant. Direct Burial Type MV-105 Copper, 260 Mils No Lead Ethylene Propylene Rubber. UL/CSA
Southwire 35kV Power Cable 1/0awg – 1250 kcmil MV-105

NLEPR Insulation 133% IL Black SIM-PVC Jacket. MV 105. Tray Rated. Sunlight Resistant. Direct Burial. Type MV-105. Copper, 420 Mils No Lead Ethylene Propylene Rubber (NL-EPR). UL/CSA

NLEPR Insulation 133% IL Black SIM-PVC Jacket. MV 105. Tray Rated. Sunlight Resistant. Direct Burial. Conductor Aluminium, 420 Mils No Lead Ethylene Propylene Rubber. Dual UL/CSA

NLEPR Insulation 133% IL Black CPE-TP Jacket. MV 105. Tray Rated. Sunlight Resistant. Direct Burial. Type MV-105 Copper, 420 Mils No Lead. Thermoplastic Chlorinated Polyethylene Jacket. UL/CSA

TRXLPE Insulation 133% IL Black SIM-PVC Jacket. MV 105. Tray Rated. Sunlight Resistant. Direct Burial. Copper, 420 Mils. Tree Retardant Cross Linked Polyethylene. UL
Note that we are able to supply in XLPE insulation, an array of other jackets from PVC, CPE, LSZH.